AAAC Conductor
The All Aluminum Alloy (AAA) Conductor is a high-performance overhead conductor used in power transmission and distribution. Made from an aluminum-magnesium-silicon alloy, it offers superior strength, conductivity, and corrosion resistance compared to All Aluminum Conductor (AAC). Its lightweight nature makes it an efficient alternative to Aluminum Conductor Steel Reinforced (ACSR), allowing for longer spans and reduced infrastructure costs. With excellent resistance to environmental degradation, it is ideal for coastal and industrial applications. AAA conductors ensure efficient power distribution with improved conductivity and minimal power losses, making them suitable for medium and high-voltage networks.

Description The conductor consists of Aluminium Magnesium - Silicon alloy wires stranded in successive layers in opposite direction and the outer layer is in the right hand direction Z. In case required, neutral grease shall be applied between the layers of AAAC except the outer layer.
Standard The construction is done as per IS 398 part 4, EN 50182, ASTM B399, IEC 61089 and other International Specifications. The requirement/specifications given by the purchaser are also taken care of.

Advantages
AAAC exhibits excellent corrosion resistance especially in sea coast areas and in polluted industrial areas due to absence of steel core.
The surface hardness of AAAC is 80 BHN as compared to 35 BHN of ACSR.
AAAC are stable up to 90 C against ACSR conductors which are stable up to 75 C.
AAAC can carry at least 15-20% extra current as compared to ACSR of equal size.
The surface hardness of AAAC is 80 BHN as compared to 35 BHN of ACSR.
This reduces the damage to surface during handling and therefore leading to lesser corona losses and ratio interference at EHV.
Applicable Standards
IS 398-4
IEC 61089
AS 1531
BS EN 50182
ASTM B399
Applications
A.A.A.C. are mainly used for overhead lines, in transmission and distribution electrical networks, having relatively long spans. They are also used a messenger to support overhead electrical cables.
01
Infant
Pulvinar ultrices porta mattis quis lobortis est facilisis purus nunc, sed semper enim dictum sed donec condimentum sodales sed non vel malesuada morbi arcu justo
- Felis mauris quisque scelerisque ac
- Sodales vel vitae tincidunt mauris arcu
- Porta sit placerat pharetra
02
Toddler
Pulvinar ultrices porta mattis quis lobortis est facilisis purus nunc, sed semper enim dictum sed donec condimentum sodales sed non vel malesuada morbi arcu justo
- Felis mauris quisque scelerisque ac
- Sodales vel vitae tincidunt mauris arcu
- Porta sit placerat pharetra
Day care membership offer
Schedule and tuition
01
Half Days
Eu vestibulum praesent pretium platea fusce amet lobortis ut malesuada neque scelerisque pulvinar quisque turpis ut etiam sit volutpat.
02
Full Days
Eu vestibulum praesent pretium platea fusce amet lobortis ut malesuada neque scelerisque pulvinar quisque turpis ut etiam sit volutpat.
03
Extended Day
Eu vestibulum praesent pretium platea fusce amet lobortis ut malesuada neque scelerisque pulvinar quisque turpis ut etiam sit volutpat.
Description
The conductor consists of Aluminium Magnesium – Silicon alloy wires stranded in successive layers in opposite direction and the outer layer is in the right hand direction Z. In case required, neutral grease shall be applied between the layers of AAAC except the outer layer.
Standard
The construction is done as per IS 398 part 4, EN 50182, ASTM B399, IEC 61089 and other International Specifications. The requirement/specifications given by the purchaser are also taken care of.
Characteristics
Strands of same diameter in Aluminium- Magnesium-Silicon group alloys, duly heat treated.
Has almost double the tensile strength of pure aluminium strands and thereby are ideal for long spans.
Suited as an alternate to ACSR or AAC depending on line engineer needs.
Low electrical losses compared to ACSR.
Superior corrosion resistance.
Ideal for seacoasts, saline and corrosion prone areas.
Suited for developing countries in order to avoid pilferage & thefts.
Application
AAAC bare conductors are used for primary and secondary overhead power transmission lines having long spans and high resistance to corrosion.